Ansul Fire Protection A 101 30lb Powder Unit 431465. Stainless Steel. Path finder 8 0 4. Stainless Steel Commercial Ansul System W 2 Tanks. Manuals, installation installation instructions, catalogs, and more for Ansul fire alarm and security devices. ANSUL® AOM-HD Monitor Assemblies provide exceptional durability for extended, continuous, or repetitive use in industrial system applications. ANSUL solutions for critical assets feature our AUTOPULSE Z-20 Addressable Releasing Panel, INERGEN iFLOW Clean-Agent Suppression, and sound engineering with our Acoustic Discharge Nozzle.
- Ansul Autopulse 442r
- Ansul Autopulse 442r Operation Manual Pdf
- Ansul Autopulse 442r Operation Manual Instructions
- Autopulse 442r Manual
- Ansul Autopulse Manual
Pre-Engineered, Stored Pressure Dry Chemical Fire Suppression
The Ansul IND-X Industrial Fire Suppression System is a pre-engineered, stored pressure dry chemical type with a fixed nozzle distribution network. It is listed with Underwriters Laboratories, Inc. (UL). The system is capable of automatic detection and actuation and/or remote manual actuation. Additional accessories are available for shutting down electrical power to equipment and shutting down the flow of gas lines.
The detection portion of the fire suppression system allows for automatic detection by means of specifically rated mechanical fusible links or electric thermal detectors. The fire suppression system has capabilities for total flooding, local application – tankside, and local application – overhead.
Ansul IND-X Applications
The Ansul IND-X Industrial Fire Suppression System is an automatic fire suppression system using FORAY dry chemical agent for Class A, B and C fires and PLUS-FIFTY C dry chemical agent for Class B and C fires, stored under pressure using dry nitrogen gas at 450 psi (31.0 bar) at 70° F (21° C). The system is designed to protect a wide variety of hazards involving flammable liquids and gases, wood and paper, and energized electrical equipment.
The system can be used on most all hazards found in industrial settings. Some examples are:
- Hazardous Storage Buildings
- Dip Tanks
- Paint Lockers
- Flammable Liquid Storage Facilities
- Stock Rooms
- Printing Machines
- Mixing Tanks
- Electrical Motors
- Pumps
- Switchgear Rooms
- Indoor Transformers
- Wood Finishing Operations
Ansul IND-X Features
- UL Listed
- Complies with UL 1254 Standard, September 29, 1998
- 25-lb., 50-lb., and 100-lb. size tanks available with FORAY dry chemical for total flooding applications
- 25-lb. and 50-lb. size tanks available with PLUS-FIFTY C dry chemical for local application overhead and local application tankside
- Three Basic Application Methods: Total Flooding, Local Application – Tankside,Local Application – Overhead
- Mechanical or Electrical Detection
- Low Temperature Total Flooding Application –20° F (–29° C)
- Multiple Total Flooding Options
The IND-X system can protect Class A, B, and C type hazards.The basic system consists of: Dry Chemical Agent Storage Tank(s), Distribution Piping and Nozzles, Control System and/or Releasing Device, Thermal or Fusible Link Detectors, and Accessories.
Agent Storage Tanks
Ansul Autopulse 442r
The IND-X system utilizes three sizes of tanks: 25-lb, 50-lb, and 100-lb. The tank assemblies consist of a factory-filled dry chemical agent tank and valve assembly. This assembly meets the appropriate Department of Transportation, (4BW500) and NFPA Standards. Each tank is finished in red enamel paint and contains either FORAY or PLUS-FIFTY C dry chemical agent pressurized with dry nitrogen. All three sizes are available with FORAY dry chemical and the 25-lb. and 50-lb. sizes are also available with PLUS-FIFTY C dry chemical.
A nameplate is affixed to the exterior and printed with contents, pressure and weight information. The nameplate is also color coded to specify either FORAY (yellow) or PLUS-FIFTY C (blue) dry chemical agent.
Distribution Piping and Nozzles
The distribution piping network is designed to properly distribute the dry chemical to the hazard areas. In the IND-X pre-engineered system; pipe sizes, maximum and minimum pipe lengths, and maximum and minimum number of pipe fittings are predetermined. There are 10 types of nozzles available for the IND-X system. Each type of nozzle has been designed and tested for specific applications and areas of coverage.
Releasing Device and/or Control System
The releasing devices consist of either an ANSUL AUTOMAN electric or mechanicalrelease or an ANSUL AUTOMAN II-C releasing device. If no supervision is required, the releasing device can be connected directly to the mechanical fusible link detectors. All releasing devices contain an LT-20-R nitrogen cartridge which supplies the pressure to actuate the tank valve and allow the dry chemical to discharge.
An AUTOPULSE control system is designed to protect fixed fire hazards. The control system can automatically actuate the releasing device on the fire suppression system after receiving an input signal from any initiating device(s); i.e., manual pull station or thermal detectors. The control system incorporates an internal power supply, on-line emergency batteries, and solid state electronics. Gulbransen organ serial numbers. The AUTOPULSE control system can utilize the AUTOPULSE 442R control panel. Other approved control system panels are also available. Contact Koetter Fire Protection for details.
Ansul Autopulse 442r Operation Manual Pdf
Fusible Link or Thermal Detectors
Fusible link detectors consist of three basic components: the bracket, linkage, and fusible link. The bracket holds the entire assembly to the mounting surface. The linkage is used to support the fusible link. The fusible link is designed to separate at a specific temperature and release the tension on the detection cable which will cause the mechanical ANSUL AUTOMAN release mechanism to actuate. The fusible links are available in six temperature ratings.
Rate compensating thermal detectors are factory preset. They are normally open,mechanical contact closure switches designed to operate at the set temperature rating or when the surrounding air temperature increases in excess of 40°F (4°C)/minute. Electric thermal detectors are available in seven preset temperatures ranging from 140°F to 725°F (60°C to 385°C).
Accessories
Accessories, such as pressure switches, micro-switches, alarm bells, pressure trips, selector switches, electric gas valves, mechanical gas valves, and flashing alarm lamps, are available for closing doors and dampers, warning personnel, shutting down HVAC equipment, shutting down elec-trical equipment, and shutting off gas lines. Accessories can be operated electrically or pneumatically.
For more information about Ansul IND-X™ Industrial Fire Suppression Systems, contact your nearest Koetter Fire Protection office today!
Details
The AUTOPULSE 542R is a six zone FACP for single and dual hazard agent releasing applications. The AUTOPULSE 542R provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing. The AUTOPULSE 542R is compatible with System Sensors i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory freeze signal when the ambient temperature falls below the detector rating of approximately 45 F (7.22 C). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to Device Compatibility Document for a complete listing of compatible devices.
Ansul Autopulse 442r Operation Manual Instructions
Four outputs are programmable as NACs (Notification Appliance Circuits) or releasing circuits. Three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board. The AUTOPULSE 542R supervises all wiring, AC voltage, battery charger and battery level.
Autopulse 442r Manual
Activation of a compatible smoke detector or any normally open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm information on the panels LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function.
Panel is new with some minor cosmetic cabinet damage, Small bend in door and dings in hinge area as shown in pics.
List Price: $1,490
List Price: $1,490
Ansul Autopulse Manual
We do not have the capabilities to test this item completely but we will guarantee it to work properly or we will give you a 100% refund (Excluding shipping) if returned to us within 14 days. Nexus mod manager witcher 2.